Functional Safety
Technical resources: IEC 61511 functional safety lifecycle, safety requirements specifications, SIL verification and PFDavg, and functional safety assessments.
Functional safety engineering support for Australian process facilities, connecting safety instrumented functions, SIL target assessment, verification and lifecycle documentation to process risk. Related services include LOPA studies and HAZOP facilitation.
See a safety function respond to a demand.
A conceptual safety instrumented function connects field detection, safety logic and a final element to achieve a defined safe state.
This is a functional overview, not a SIL verification. Response time, diagnostic coverage, proof testing, common cause and lifecycle requirements must be evaluated.
Keep the safety function
connected to the hazard.
Functional safety should remain traceable from the hazardous event through the required risk reduction and into the implemented safety function. We support projects and operating assets in keeping that connection clear throughout the lifecycle.
Understand risk
Trace the safety function back to the hazardous scenario and required risk reduction.
Define requirements
Set clear functional intent, trip conditions, timing and performance requirements.
Assure design
Support architecture, verification and evidence through project delivery.
Maintain lifecycle
Preserve integrity through testing, operation, bypasses and modification.
Clear from scope
to close-out.
The work focuses on functional intent, independence, architecture, verification and lifecycle controls so the implemented protection continues to do what the original risk assessment required.
Keep each safety function tied to the hazardous event and the specific risk reduction it must deliver.
Define trip logic, timing, process state, reset philosophy and performance requirements clearly.
Check architecture, independence, diagnostics and evidence against the intended SIL and operating context.
Protect integrity through proof testing, bypass management, modification and periodic review.
Need functional safety support?
Tell us where you are in the lifecycle, from SIL determination and requirements definition through design review, verification or modification. We can target the assurance effort to the actual gap.
For an initial discussion, outline the process or facility type, the project stage, the decision or deliverable you need and any target date. Note which records are available, such as hazard-study actions, an existing safety requirements specification or previous verification reports. A high-level summary is enough to start; only share project documents you are authorised to disclose.